Planning, installation and remote monitoring of refrigeration, air conditioning and heat pump systems in Koblenz.

Hüttenbrauck Kälte- und Klimatechnik GmbH
Koblenz (DE)New on Amplifa
About Hüttenbrauck
Hüttenbrauck Kälte- und Klimatechnik GmbH in Koblenz is a family business whose origins date back to 1933. The company plans, designs and installs refrigeration and air conditioning technology, including room cooling, cold storage rooms, display cases, commercial refrigeration and heat recovery. In the field of air conditioning it implements systems for office buildings, hospitals, IT and server rooms, retail spaces, swimming pools and residential spaces; the product range includes single-split and multi-split systems from Mitsubishi Electric as well as ceiling cassettes and floor-standing units. In addition, the company offers heat pumps for heating and hot water requirements, remote monitoring of refrigeration and air conditioning systems using the NovaAlert system including a backup GSM alert system, and a 24-hour emergency service for commercial refrigeration systems. Since 1995 the business has operated as a GmbH under managing director Dirk Hüttenbrauck, certified master refrigeration system installer, with an average annual revenue of around €2.6 million. The company is located at its premises in the Arenberg industrial park in Koblenz.
- Site
- Koblenz
- Processes
- Refrigeration technology (room cooling, cold storage rooms, display cases, commercial, Air conditioning technology (office buildings, hospitals, IT and retail spaces, swimming pools,, Heat pumps for heating and hot water requirements, Remote monitoring of refrigeration and air conditioning systems (NovaAlert monitoring system,, 24-hour emergency service for commercial refrigeration systems, Planning and project design of refrigeration and air conditioning technology (consulting by master, Construction of combined refrigeration systems (e.g. two combined systems for a transshipment, Single-room air conditioning (single-split: one indoor unit connected to one outdoor unit)
- Materials
- Refrigerant R134a, Refrigerant R 32, Refrigerant R32
- Certificates
- Proof of tax liability (§13b UStG, Koblenz Tax Office), Proof of tax liability §13b UStG (German VAT Act)
- Founded
- 1933
- Industries
- IT system houses/server rooms (computer rooms), Office buildings, Hospitals, Retail spaces, Swimming pools, Gastronomy
- 01
Consulting and planning
- 02
Project design
- 03
System installation
- 04
Remote monitoring (NovaAlert)
- 05
24-hour emergency service and maintenance
Refrigerants and Technology
Refrigerant R134a
Used in combined refrigeration systems, e.g. for the transshipment warehouse of Frigosped.
Refrigerant R32
Refrigerant of the Mitsubishi Electric split and multi-split air conditioning units used.
Locations

Koblenz
DEHead office, planning, project design and installation
- Materials
- Refrigerant R134a, R32
- Single-split and multi-split air conditioning units (Mitsubishi Electric)
- Ceiling cassettes and floor-standing units
- Combined refrigeration systems with reciprocating compressors
- NovaAlert remote monitoring system with backup GSM alert system NOVA-ALERT
Reference Systems







Inside the production



Industries
Processes & technical limits
| Processes | Tolerance | Max. part | Weight | Lot size | Materials |
|---|---|---|---|---|---|
| Refrigeration technology (room cooling, cold storage rooms, display cases, commercialInstallation | – | – | – | – | Refrigerant R134a, Refrigerant R32 |
| Air conditioning technology (office buildings, hospitals, IT and retail spaces, swimming pools,Installation | – | – | – | – | – |
| Heat pumps for heating and hot water requirementsInstallation | – | – | – | – | – |
| Remote monitoring of refrigeration and air conditioning systems (NovaAlert monitoring system,Testing | – | – | – | – | – |
| 24-hour emergency service for commercial refrigeration systemsInstallation | – | – | – | – | – |
| Planning and project design of refrigeration and air conditioning technology (consulting by masterEngineering | – | – | – | – | – |
| Construction of combined refrigeration systems (e.g. two combined systems for a transshipmentInstallation | – | – | – | – | Refrigerant R134a |
| Single-room air conditioning (single-split: one indoor unit connected to one outdoor unit)Installation | – | – | – | – | Refrigerant R 32 |
| Multi-room air conditioning (multi-split: several indoor units connected to one outdoor unit)Installation | – | – | – | – | Refrigerant R 32 |
10 Anlagen & Maschinen
| Machine | Manufacturer / model | Quantity | Working area | Year built | Site |
|---|---|---|---|---|---|
| Split air conditioner wall unit (indoor unit) | Mitsubishi Electric MSZ-LN25VG / MSZ-LN35VG / MSZ-LN50VG / MSZ-LN60VG | – | – | – | – |
| Split air conditioner wall unit (indoor unit) | Mitsubishi Electric MSZ-AP20VG / MSZ-AP25VG / MSZ-AP35VG / MSZ-AP42VG / MSZ-AP50VG | – | – | – | – |
| Split air conditioner designer wall unit (indoor unit) | Mitsubishi Electric MSZ-EF25VG / MSZ-EF35VG / MSZ-EF42VG / MSZ-EF50VG | – | – | – | – |
| Floor console unit (floor-standing unit) | Mitsubishi Electric MFZ-KT25VG / MFZ-KT35VG / MFZ-KT50VG / MFZ-KT60VG | – | – | – | – |
| 4-way ceiling cassette (Euro grid dimension, installation height 245 mm) | Mitsubishi Electric SLZ-M25FA / SLZ-M35FA / SLZ-M50FA / SLZ-M60FA | – | – | – | – |
| Under-ceiling cassette unit | Mitsubishi Electric MLZ-KP25VF / MLZ-KP35VF / MLZ-KP50VF | – | – | – | – |
| Floor-standing unit (low height) | Mitsubishi Electric MFZ-EF25VG / MFZ-EF35VG / MFZ-EF42VG / MFZ-EF50VG | – | – | – | – |
| Multi-split outdoor units (for several indoor units) | Mitsubishi Electric MXZ-2 / MXZ-3 / MXZ-4 / MXZ-5 / MXZ-6 | – | – | – | – |
| Reciprocating compressor (in combined refrigeration systems, 6 per system) | – | – | – | – | – |
| Remote monitoring and GSM alert system | NOVA-ALERT / NovaAlert | – | – | – | – |
Additional services
Reference customers
Quality and Reliability
Smooth order processing, a 24-hour emergency service for commercial refrigeration systems and a motivated, trained team ensure execution quality. Remote monitoring systems such as NovaAlert with a backup GSM alert system monitor systems even during power or network failures.
| Evidence | Koblenz |
|---|---|
| Proof of tax liability §13b UStG (German VAT Act) |
Company History
- 1933
Founded by Ernst Hüttenbrauck (electric motors); reconstruction after the Second World War
- 1971
Gerd Hüttenbrauck takes over the business as a master refrigeration technician
- 1984
Dirk Hüttenbrauck joins the company; apprenticeship as a refrigeration system builder
- 1994
Dirk Hüttenbrauck passes master craftsman examination; relocation to the company building in the Arenberg industrial park, Koblenz
- 1995
Conversion into a GmbH; Dirk Hüttenbrauck becomes managing director
- 2001
Renate Hüttenbrauck takes over secretariat, order processing and controlling as authorized officer
- 2004
Marcel Maus becomes Rhineland-Palatinate state champion in the journeyman examination and achieves 2nd place as refrigeration system builder Europe-wide
- 2012
Start of support for the Stommel Foundation in Urbar
- 2025
Expansion of the remote monitoring offering (NovaAlert); update of IT security and data protection