
DAkkS-accredited calibration laboratory in Dresden for electrical, thermodynamic and mechanical measurands

LDH Kalibrierservice GmbH
DresdenNew on Amplifa
About LDH Kalibrierservice GmbH
LDH Kalibrierservice GmbH was founded in April 2012 in Dresden and took over a calibration laboratory that had been active in the market for more than 25 years. The owner-managed company operates a DAkkS-accredited calibration laboratory (D-K-18673-01-00) according to DIN EN ISO/IEC 17025:2018 for more than 16 measurands. Calibration is performed manufacturer-independently in the fields of electrical measurands, time and frequency, temperature and humidity, dimensional and mechanical measurands, vibration, acoustics, optics and telecommunications – as DAkkS calibration, factory calibration, on-site calibration or customer-specific calibration. In addition, the company offers adjustment, repair, measuring equipment management, MSA/measuring equipment capability studies, training as well as a pick-up and delivery service. On 816 m² of climate-controlled laboratory and office space, 18 employees work with modern reference standard technology, including from FLUKE, and in-house software development for automated calibration routines and certificate creation. Since 2023, LDH has been a full member of the German Calibration Service (DKD).
- Site
- Dresden
- Processes
- Calibration of electrical measurands (DC voltage, DC current, AC voltage, AC current,, Calibration of time and frequency (frequency 1 mHz to 26.5 GHz, time interval 1 ns to 10 s,, Calibration of thermodynamic measurands (resistance thermometers, thermocouples, block calibrators, Calibration of dimensional measurands (smooth and thread gauges, calipers, dial indicators,, Calibration of mechanical measurands (pressure -0.9 to 3 bar rel / -0.1 to 10 bar abs, force,, DAkkS-accredited calibration according to DIN EN ISO/IEC 17025:2018 (more than 16 measurands), On-site calibration, Customer-specific calibration
- Materials
- Electrical measurands, Time and frequency, Thermodynamic measurands, Dimensional measurands, Mechanical measurands
- Certificates
- DIN EN ISO/IEC 17025:2018 (DAkkS accreditation), Membership in the German Calibration Service (DKD), DIN EN ISO/IEC 17025:2018 (DAkkS), German Calibration Service (DKD, full member), EA-MLA mark on calibration certificates
- Founded
- 2012-04
- Employees
- 18
- Industries
- Electrical measurement technology, RF/communications technology, Temperature and humidity measurement technology, Mechanical measurement technology, Dimensional measurement technology, Vibration/acoustics
- 01
Consulting on the use of measuring and testing equipment
- 02
Pick-up and delivery service
- 03
Calibration (DAkkS, factory, on-site, customer-specific)
- 04
Adjustment, repair and overhaul
- 05
Certificate creation and measuring equipment management
Measurands and Reference Standards
Electrical measurands
Calibration of DC and AC voltage/current, resistance, capacitance, inductance, oscilloscopes, RF and EMC measurement technology as well as electrical safety.
Time and frequency
Frequency 1 mHz to 26.5 GHz and time intervals 1 ns to 10 s, traceable via a GPS-supported rubidium oscillator (basic accuracy < 1e-12).
Thermodynamic measurands
Calibration of thermocouples, resistance thermometers, block calibrators and baths from -95 °C to +660 °C as well as relative humidity 5–95 %.
Dimensional measurands
Calibration of gauges, calipers, dial indicators, micrometers and protractors.
Mechanical measurands
Pressure up to 10 bar abs, force, scales up to 75 kg and torque up to 1500 Nm.
Location

Dresden
DEDAkkS-accredited calibration laboratory with laboratory, office and training room
- Materials
- Electrical measurands, time/frequency, temperature/humidity, dimensional and mechanical measurands, optics
- FLUKE multifunction calibrators 5520A/5522A
- FLUKE 5322A (electrical safety)
- FLUKE transconductance amplifier 52120A
- GPS-supported rubidium oscillator as time standard
- rotronic temperature/humidity mixed generator HG2
- MBW dew point hygrometer with dew point mirror
- SPRT/IPRT thermometers
- Temperature baths (-45 to +160 °C)
- Temperature block calibrators (-95 to +650 °C)
- PXI/PXIe/PCI/PCIe chassis for modular measurement systems
Calibrated Measuring and Testing Equipment






Inside the production




Industries
Processes & technical limits
| Processes | Tolerance | Max. part | Weight | Lot size | Materials |
|---|---|---|---|---|---|
| Calibration of electrical measurands (DC voltage, DC current, AC voltage, AC current,Testing | – | – | – | – | – |
| Calibration of time and frequency (frequency 1 mHz to 26.5 GHz, time interval 1 ns to 10 s,Testing | – | – | – | – | – |
| Calibration of thermodynamic measurands (resistance thermometers, thermocouples, block calibratorsTesting | – | – | – | – | – |
| Calibration of dimensional measurands (smooth and thread gauges, calipers, dial indicators,Testing | – | – | – | – | – |
| Calibration of mechanical measurands (pressure -0.9 to 3 bar rel / -0.1 to 10 bar abs, force,Testing | – | – | – | – | – |
| DAkkS-accredited calibration according to DIN EN ISO/IEC 17025:2018 (more than 16 measurands)Testing | – | – | – | – | – |
| On-site calibrationTesting | – | – | – | – | – |
| Customer-specific calibrationTesting | – | – | – | – | – |
| Adjustment, maintenance, repair and overhaul of measuring instrumentsTesting | – | – | – | – | – |
| Measuring equipment management (web browser)Testing | – | – | – | – | – |
| Measuring equipment capability / MSA (measurement system analyses)Testing | – | – | – | – | – |
| Training on calibration procedures and measurement uncertainty (MU)Engineering | – | – | – | – | – |
| Pick-up and delivery serviceTesting | – | – | – | – | – |
| Calibration of vibration/acceleration and acoustics/sound (sound level meters)Testing | – | – | – | – | – |
| Calibration of optics (wavelengths 800 to 1600 nm, level 10 to -60 dBm)Testing | – | – | – | – | – |
| Calibration of telecommunications (bit error, jitter, frames)Testing | – | – | – | – | – |
10 Anlagen & Maschinen
| Machine | Manufacturer / model | Quantity | Working area | Year built | Site |
|---|---|---|---|---|---|
| Multifunction calibrator | FLUKE 5520A/5522A | – | – | – | Dresden |
| Multifunction calibrator electrical safety | FLUKE 5322A | – | – | – | Dresden |
| Transconductance amplifier | FLUKE 52120A | – | – | – | Dresden |
| GPS-supported rubidium oscillator (time standard) | – | – | Basic accuracy < 1e-12 | – | Dresden |
| Temperature/humidity mixed generator | rotronic HG2 | – | 0...60°C, 5...95% RH | – | Dresden |
| Dew point hygrometer with dew point mirror (reference standard) | MBW | – | – | – | Dresden |
| SPRT/IPRT thermometers | – | – | -95...+660°C | – | Dresden |
| Temperature baths | – | – | -45°C to +160°C | – | Dresden |
| Temperature block calibrators | – | – | -95°C to +650°C | – | Dresden |
| PXI/PXIe/PCI/PCIe chassis for modular measurement systems | – | – | – | – | Dresden |
Additional services
Quality and Accreditation
Calibrations are performed according to DIN EN ISO/IEC 17025:2018 under DAkkS accreditation D-K-18673-01-00 with traceability to national standards (among others UTC via GPS-supported rubidium oscillator). Conformity assessments are carried out according to selectable decision rules in accordance with ILAC-G8:09/2019.
| Evidence | Dresden |
|---|---|
| DIN EN ISO/IEC 17025:2018 (DAkkS) | |
| German Calibration Service (DKD, full member) | |
| EA-MLA mark on calibration certificates |
Company History
- 2012
Foundation of LDH Kalibrierservice GmbH in April 2012 in Dresden; takeover of a calibration laboratory active for more than 25 years
- 2023
Admission as a full member of the German Calibration Service (DKD), certificate dated 09.02.2023
- 2026
New combined MLA mark from EA and DAkkS as well as a modernized DKD logo on the calibration certificates