Accredited service provider for calibration, test equipment management, qualification and validation.

Testo Industrial Services GmbH
Wien · Kirchzarten · Essen · Dachau · Winsen (Luhe) · Hamburg · Mörfelden-Walldorf · Gera · Kulmbach · Egg (Zürich) · Givisiez · Forbach · Genas · Criquebeuf-sur-Seine · Cabrils (Barcelona) · MataróNew on Amplifa
About Testo Industrial Services
Testo Industrial Services GmbH is a company specialized in metrological services for calibration, test equipment management, qualification and validation. The company is accredited as a calibration laboratory according to DIN EN ISO/IEC 17025:2018 and covers more than 300 calibration methods, including temperature (-80 to 1200 °C), humidity, air velocity, pressure (absolute pressure up to 1000 bar and smallest pressures in the pascal range), electrical quantities and frequency as well as mechanical rotational speed. Calibrations are performed manufacturer-independently in accredited laboratories (ÖKD/DAkkS), as ISO/factory calibration or as on-site calibration. In addition, the company offers qualification of cleanrooms, systems and utilities according to GxP standards, validation, test equipment management with the PRIMAS solution, repair service, metrological testing services such as initial sample inspection reports and HV tests, as well as seminars. The company, founded in 1981 in Vienna, belongs to Testo SE & Co. KGaA and employs more than 1.600 employees at locations in Austria, Germany, Switzerland, France and Spain.
- Site
- Wien
- Processes
- Calibration (accredited ÖKD/DAkkS calibration, over 300 methods according to DIN EN ISO/IEC, ISO/factory calibration, On-site calibration, Temperature calibration (measuring range -80 ... 1200 °C), Humidity calibration / relative humidity, Pressure calibration (including absolute pressure, measuring range up to 1000 bar, smallest, Air velocity calibration, Electrical metrology calibration / electrical quantities and frequency
- Materials
- Temperature calibration (Thermator II, MC6-T), Humidity calibration (Huminator II), Pressure calibration (Pneumator, Beamex ePG), Electrical metrology, Dimensional metrology
- Certificates
- ISO 9001:2015, Accreditation DIN EN ISO/IEC 17025:2018 (calibration laboratory, over 300, Accreditation as verification office for temperature measuring instruments, DIN EN ISO/IEC 17025:2018 (calibration laboratory), Verification office for temperature measuring instruments
- Founded
- 1981
- Employees
- 1.600
- Industries
- Pharma, Automotive, Medical technology, Biotech & Life Sciences, Logistics, Energy suppliers & power plants
- 01
Calibration (laboratory and on-site)
- 02
Test equipment management (PRIMAS)
- 03
Pick-up and delivery service / logistics
- 04
Qualification (cleanrooms, systems & utilities)
- 05
Validation
- 06
Repair
- 07
Consulting and seminars
Calibration equipment and metrology
Temperature calibration (Thermator II, MC6-T)
Multifunction temperature calibrators for sensors, infrared measuring devices and thermal imaging cameras in the range -35 to 660 °C.
Humidity calibration (Huminator II)
Precision humidity generator with measuring chamber Ø 160 mm for up to 5 probes or loggers in parallel.
Pressure calibration (Pneumator, Beamex ePG)
Pressure calibrators for differential, relative and absolute pressure from 1 hPa to 1000 bar.
Electrical metrology
Laboratory for electrical quantities and frequency with bead bath for HV/insulation tests up to 5 kV.
Dimensional metrology
Coordinate measuring machines, fringe light projector and 3D scanning for components up to 3 m measuring range.
Industries
Processes & technical limits
| Processes | Tolerance | Max. part | Weight | Lot size | Materials |
|---|---|---|---|---|---|
| Calibration (accredited ÖKD/DAkkS calibration, over 300 methods according to DIN EN ISO/IECTesting | – | – | – | – | – |
| ISO/factory calibrationTesting | – | – | – | – | – |
| On-site calibrationTesting | – | – | – | – | – |
| Temperature calibration (measuring range -80 ... 1200 °C)Testing | – | – | – | – | – |
| Humidity calibration / relative humidityTesting | – | – | – | – | – |
| Pressure calibration (including absolute pressure, measuring range up to 1000 bar, smallestTesting | – | – | – | – | – |
| Air velocity calibrationTesting | – | – | – | – | – |
| Electrical metrology calibration / electrical quantities and frequencyTesting | – | – | – | – | – |
| Mechanical rotational speed calibrationTesting | – | – | – | – | – |
| Calibration of mass flow, level (mass), conductivity, pH value, oxygen saturationTesting | – | – | – | – | – |
| Calibration of climate chambersTesting | – | – | – | – | – |
| Accredited calibration of KEYENCE measuring systems (product lines IM, VHX, VK, VR, LM; measuringTesting | 0,5 μm | 300 mm | – | – | – |
| Dimensional metrology / coordinate measuring technology (CMM), optical metrologyTesting | – | 3 m | – | – | – |
| HV tests / electric dielectric strength/insulation testing according to DIN 61010-31 in the beadTesting | – | – | – | – | – |
| Machine capability study (MFU) according to VDI/VDE 2645 (screw-cap related) and DIN ISO 22514Testing | – | – | – | – | – |
| Measurement system analysis (MSA) method 1 according to AIAG / capability proof according to VDATesting | – | – | – | – | – |
| Suitability tests and comparison measurements (thermodynamic and dimensional)Testing | – | – | – | – | – |
| Density measurements (TrueDyne density sensors)Testing | – | – | – | – | – |
| Verification of temperature measuring instruments (verification office)Testing | – | – | – | – | – |
| Repair of electrical and thermodynamic test equipment and measuring devicesEngineering | – | – | – | – | – |
| Test equipment management (PRIMAS: calibration cycles, processes, documentation, logistics, ITEngineering | – | – | – | – | – |
| Qualification of cleanrooms (filter leak test, recovery times, cleanliness class, volume flow,Testing | – | – | – | – | – |
| Qualification of systems and utilities (HVAC systems, process gases, water systems, sterilizers,Testing | – | – | – | – | – |
| Testing of process gases according to ISO 8573, Ph.Eur. (particle content, microbiological status,Testing | – | – | – | – | – |
| Sterilization validation (autoclaves, steam sterilizers, hot-air sterilizers/tunnels,Testing | – | – | – | – | – |
| Cleaning validation (CIP, dishwashers, standing time validation)Testing | – | – | – | – | – |
| Validation (cleaning, process, transport, computer/software validation)Testing | – | – | – | – | – |
| Qualification of warehouses and transport systems (GxP)Testing | – | – | – | – | – |
| Temperature and climate mappingsTesting | – | – | – | – | – |
| Consulting quality assurance (measurement system analysis, SPC, Automotive Core Tools, SixEngineering | – | – | – | – | – |
| Seminars & workshops (measurement uncertainties according to GUM, test equipment officers,Engineering | – | – | – | – | – |
| Pick-up and delivery service / logistics for test equipmentEngineering | – | – | – | up to 10 kg (nox Austria cooperation) | – |
| Distribution of calibration equipment (Thermator II, Huminator II, Pneumator, Beamex calibrators)Engineering | – | – | – | – | – |
18 Anlagen & Maschinen
| Machine | Manufacturer / model | Quantity | Working area | Year built | Site |
|---|---|---|---|---|---|
| Wind tunnel (accredited) | – | 1 | – | – | Wien |
| Laboratory for electrical quantities and frequency | – | 1 | – | 2009 | Wien |
| Electrical laboratory with bead bath for insulation tests | – | 1 | Voltage ranges up to 5 kV | – | Kirchzarten (DE) |
| Dimensional laboratory with coordinate measuring machines (CMM), fringe light projector and 3D | – | – | Measuring range up to 3 m | – | – |
| Cleanroom training center with airlock | – | 1 | 90 m2, ISO classes 5–8 (GMP B–D), differential pressure cascade | – | Kirchzarten (DE) |
| Training system for calibrations (temperature, humidity, pressure, rotational speed, flow/level, | – | 1 | – | – | Kirchzarten (DE) |
| Multifunction temperature calibrator Thermator II | Testo Industrial Services Thermator II | – | -35 … 165 °C (dry block), -25 … 150 °C (surface); stability ±0,005 °C | – | – |
| Precision humidity generator Huminator II | Testo Industrial Services Huminator II | – | 5 °C to 50 °C, 5 %RH to 95 %RH; measuring chamber Ø 160 mm; up to 5 probes/loggers in parallel | – | – |
| Pressure calibrator Pneumator | Testo Industrial Services Pneumator | – | Pressure ranges 1, 10, 100 or 1000 hPa | – | – |
| Multifunction process calibrator Beamex MC6 (documenting calibrator and field communicator) | Beamex MC6 | – | Pressure, temperature, electrical signals; HART, Foundation Fieldbus H1, Profibus PA | – | – |
| Explosion-proof multifunction calibrator Beamex MC6-Ex | Beamex MC6-Ex | – | ATEX/IECEx Zone 0; Ex ia IIC T4 Ga | – | – |
| Temperature calibrator & multifunction calibrator Beamex MC6-T (T150: -30 to 150 °C; T660: 50 to | Beamex MC6-T150 / MC6-T660 | – | -30 to 660 °C (depending on model) | – | – |
| Mobile electric vacuum and overpressure calibration pump Beamex ePG | Beamex ePG | – | -0,85 … 20 bar | – | – |
| Reference sets for cleanroom measurements (particle counter, aerosol generator, dilution stage) | – | 17 | – | – | – |
| Reference sets for calibration of the measured quantity pressure | – | 12 | – | – | – |
| Temperature and humidity loggers | – | 1.400 | – | – | – |
| Loggers for validation of sterilization processes | – | 76 | – | – | – |
| Temperature baths, blocks and humidity generators (auxiliary equipment) | – | – | – | – | – |
Additional services
Reference customers
Quality and accreditation
Testo Industrial Services is certified according to ISO 9001:2015 and accredited as a calibration laboratory according to DIN EN ISO/IEC 17025:2018 for over 300 methods. In Vienna there is additionally an approval as a verification office for temperature measuring instruments.
| Evidence | Wien | Kirchzarten | Egg (Zürich) |
|---|---|---|---|
| ISO 9001:2015 | |||
| DIN EN ISO/IEC 17025:2018 (calibration laboratory) | |||
| Verification office for temperature measuring instruments |
Company history
- 1981
Founding of the Testo GmbH branch in Vienna
- 1995
Establishment of the calibration station in Vienna
- 1996
Initial accreditation for temperature, humidity, air velocity and pressure
- 1998
Approval of a verification office for the verification of temperature measuring instruments
- 2000
Accreditation of the new wind tunnel
- 2002
Extension of the accredited measuring range to -80...1200 °C
- 2005
Accreditation for on-site calibrations temperature and pressure; verification office; absolute pressure up to 1000 bar
- 2007
Accreditation of the new humidity method
- 2008
Extension of the pressure measuring range into the pascal range
- 2009
Establishment of the laboratory for electrical quantities and frequency
- 2014
The calibration station in Vienna becomes part of Testo Industrial Services GmbH
- 1996-2026
30 years of accreditation as a calibration laboratory, continuous expansion (pressure, electrical metrology, mechanical rotational speed)
- 2026
Expansion of the accredited scope of services at the Vienna site